Product description
We provide a 3-year warranty on this product.
The UT202F digital clamp meter is designed to measure AC and DC voltages up to 600V, AC currents up to 600A and the frequency of voltages up to 600V. It features overvoltage protection against voltages exceeding 600 V across all ranges, as well as an audible and visual alarm. The four-digit, multi-segment display measures 37 x 25 mm, with backlighting and a fast refresh rate (3 times per second) . The jaw opening allows measurement on cables with a diameter of up to 28 mm. Non-contact electric field detection (NCV) enables the detection of live conductors at two sensitivity levels – EFLo and - EFHi – for low-voltage distribution systems at 110 V/50/60 Hz and 230 V/50/60 Hz. The included probe – a tip cover for the test leads – enables measurements on low-voltage distribution systems in CAT III category without the risk of arcing. Without the tip covers, the test leads can only be used to measure on low-voltage circuits in CAT II. Power supply: 2 x 1.5V R03 batteries. The meter’s current consumption is approx. 1.8 mA. The circuit features an automatic power-saving function. Power consumption in sleep mode is <11 µA, which effectively extends battery life to approximately 400 hours.
Product specifications: - measurement of voltage, current and frequency of high voltage up to 600 V - frequency measurement from 10 Hz to 10 MHz
- Capacitance measurement from 6 nF to 60 mF - Ratio (relative) measurement of voltage and capacitance - Multi-segment display and audible/visual alarm - Protection against voltages exceeding 600 V across all ranges
- non-contact detection of live conductors - automatic range switching - measurement accuracy for current and voltage is guaranteed within 1 per cent to 100 per cent of the ranges
Technical specifications: 1. AC current measurement (ranges / resolution / accuracy): 6,000 A / 0.001 A / 50 Hz to 100 Hz ±(4.0% + 10)
60.00 A / 0.010 A / 50 Hz ~ 100 Hz ±(2.0% + 10) 600.0 A / 0.100 A / 50 Hz ~ 100 Hz ±(2.0% + 10)
- Frequency monitoring accuracy when measuring AC current in the range of 50 to 100 Hz is ±(1.0% + 5) at a resolution of 0.1 Hz - Overload protection at 620 A
2. AC voltage measurement (range / resolution / accuracy): 6.000 V / 0.001 V / 10 Hz to 10 kHz ±(1.0% + 5)
60.00 V / 0.010 V / 10 Hz to 10 kHz ±(0.8% + 5) 600.0 V / 0.100 V / 10 Hz to 10 kHz ±(0.8% + 5)
- Frequency monitoring accuracy when measuring AC voltage in the range 10 to 10k ±(1.0%+5) at a resolution of 0.01Hz to 0.01kHz - Overload protection at 600Vrms
- Input impedance approx. 10 MG? 3. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ±(0.7 % + 3)
6.000 V / 0.001 V / ±(0.5 % + 2) 60.00 V / 0.010 V / ±(0.7 % + 3)
600.0 V / 0.100 V / ±(0.7 % + 3) - input impedance approx. 10 M? - overload protection at 600 Vrms
4. Resistance measurement (ranges / resolution / accuracy): 600.0 ? / 0.1 ? / ±(1.0% + 2)
6,000 k? / 0.001 k? / ±(0.8% + 2) 60.00 k? / 0.01 k? / ±(0.8% + 2)
600.0 k? / 0.1 k? / ±(0.8% + 2) 6.000 M? / 0.001 M? / ±(2.0% + 5)
60.00 M? / 0.01 M? / ±(2.0% + 5) - overload protection at 600 Vrms 5. Capacitance measurement (ranges / resolution / accuracy):
6,000 nF / 0.001 nF / ±(4.0% + 10) 60.00 nF / 0.01 nF / ±(4.0% + 10)
600.0 nF / 0.1 k nF / ±(4.0% + 10) 6,000 µF / 0.001 µF / ±(4.0% + 5)
60.00 µF / 0.01 µF / ±(4.0% + 5) 600.0 µF / 0.1 µF / ±(4.0% + 5)
6.000 mF / 0.001 mF / ±10.0% 60.00 mF / 0.01 mF / ±10.0% - overload protection at 600 Vrms
6. Frequency and capacitance measurement (ranges / resolution / accuracy): frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ±(0.1% + 4)
Duty cycle: 0.1 to 99.9 per cent / 0.1 per cent / ±(3.0 per cent + 5) - Note 1) Measurement sensitivity:
?100 kHz: 200 mV rms ? input amplitude ? 30 V rms >100 kHz–1 MHz: 600 mV rms ? input amplitude ? 30 V rms
>1 MHz to 10 MHz: 1 V RMS ? input amplitude ? 30 V RMS - Note 2) Duty cycle measurement is only applicable for square waves ? 10 kHz, amplitude: 1 V p-p
Frequency ? 1 kHz Duty cycle: 10.0%–95.0% Frequency > 1 kHz Duty cycle: 30.0%–70.0%
- Overload protection at 600 Vrms 7. Circuit continuity test:
- if the measured resistance is less than 10 ?, the buzzer sounds to indicate a continuous circuit - if the measured resistance is greater than 31 ?, the buzzer does not sound to indicate an open circuit - open-circuit voltage
Product specifications: - measurement of voltage, current and frequency of high voltage up to 600 V - frequency measurement from 10 Hz to 10 MHz
- Capacitance measurement from 6 nF to 60 mF - Ratio (relative) measurement of voltage and capacitance - Multi-segment display and audible/visual alarm - Protection against voltages exceeding 600 V across all ranges
- non-contact detection of live conductors - automatic range switching - measurement accuracy for current and voltage is guaranteed within 1 per cent to 100 per cent of the ranges
Technical specifications: 1. AC current measurement (ranges / resolution / accuracy): 6,000 A / 0.001 A / 50 Hz to 100 Hz ±(4.0% + 10)
60.00 A / 0.010 A / 50 Hz ~ 100 Hz ±(2.0% + 10) 600.0 A / 0.100 A / 50 Hz ~ 100 Hz ±(2.0% + 10)
- Frequency monitoring accuracy when measuring AC current in the range of 50 to 100 Hz is ±(1.0% + 5) at a resolution of 0.1 Hz - Overload protection at 620 A
2. AC voltage measurement (range / resolution / accuracy): 6.000 V / 0.001 V / 10 Hz to 10 kHz ±(1.0% + 5)
60.00 V / 0.010 V / 10 Hz to 10 kHz ±(0.8% + 5) 600.0 V / 0.100 V / 10 Hz to 10 kHz ±(0.8% + 5)
- Frequency monitoring accuracy when measuring AC voltage in the range 10 to 10k ±(1.0%+5) at a resolution of 0.01Hz to 0.01kHz - Overload protection at 600Vrms
- Input impedance approx. 10 MG? 3. DC voltage measurement (range / resolution / accuracy): 600.0 mV / 0.100 mV / ±(0.7 % + 3)
6.000 V / 0.001 V / ±(0.5 % + 2) 60.00 V / 0.010 V / ±(0.7 % + 3)
600.0 V / 0.100 V / ±(0.7 % + 3) - input impedance approx. 10 M? - overload protection at 600 Vrms
4. Resistance measurement (ranges / resolution / accuracy): 600.0 ? / 0.1 ? / ±(1.0% + 2)
6,000 k? / 0.001 k? / ±(0.8% + 2) 60.00 k? / 0.01 k? / ±(0.8% + 2)
600.0 k? / 0.1 k? / ±(0.8% + 2) 6.000 M? / 0.001 M? / ±(2.0% + 5)
60.00 M? / 0.01 M? / ±(2.0% + 5) - overload protection at 600 Vrms 5. Capacitance measurement (ranges / resolution / accuracy):
6,000 nF / 0.001 nF / ±(4.0% + 10) 60.00 nF / 0.01 nF / ±(4.0% + 10)
600.0 nF / 0.1 k nF / ±(4.0% + 10) 6,000 µF / 0.001 µF / ±(4.0% + 5)
60.00 µF / 0.01 µF / ±(4.0% + 5) 600.0 µF / 0.1 µF / ±(4.0% + 5)
6.000 mF / 0.001 mF / ±10.0% 60.00 mF / 0.01 mF / ±10.0% - overload protection at 600 Vrms
6. Frequency and capacitance measurement (ranges / resolution / accuracy): frequency: 10 Hz to 10 MHz / 0.01 Hz to 0.01 MHz / ±(0.1% + 4)
Duty cycle: 0.1 to 99.9 per cent / 0.1 per cent / ±(3.0 per cent + 5) - Note 1) Measurement sensitivity:
?100 kHz: 200 mV rms ? input amplitude ? 30 V rms >100 kHz–1 MHz: 600 mV rms ? input amplitude ? 30 V rms
>1 MHz to 10 MHz: 1 V RMS ? input amplitude ? 30 V RMS - Note 2) Duty cycle measurement is only applicable for square waves ? 10 kHz, amplitude: 1 V p-p
Frequency ? 1 kHz Duty cycle: 10.0%–95.0% Frequency > 1 kHz Duty cycle: 30.0%–70.0%
- Overload protection at 600 Vrms 7. Circuit continuity test:
- if the measured resistance is less than 10 ?, the buzzer sounds to indicate a continuous circuit - if the measured resistance is greater than 31 ?, the buzzer does not sound to indicate an open circuit - open-circuit voltage