UNI-T UT197PV Multimeter – Solar PRO – unboxed
Opened
Solární multimetr - True RMS, displej 6000 číslic, měření AC/DC napětí až 1000V, výkon AC až 1500 kVA a DC až 2500 kVA, měření výstupu VFD, externí kleště AC/DC 1000A (UT-CS07), krytí IP67, odolnost proti pádu ze 5 m, provozní teplota -40 až 55°C, př
Last piece
Expected shipping:
16.10.2026
Regular price
5.849,00 Kč
4.833,88 Kč
excl. VAT
Unit price
/
Unavailable
UNI-T | SKU:
90330488
Product description
We provide a 3-year warranty on this product.
The UT197PV - Solar PRO professional multimeter is a robust, high-precision true RMS handheld multimeter designed for industrial use. Its key features include an IP67 rating for resistance to dust and water, and the ability to withstand a drop from a height of up to 5 metres. This multimeter is ideal for demanding outdoor conditions (-40°C to 55°C), such as dampness, sand and extreme cold. It has a wide range of applications in the energy sector, ventilation systems, renewable energy and environmental protection, etc.
Product specifications: - True RMS measurement with 6,000 digits - AC/DC voltage: 1,000 V - Power measurement: 1,500 kVA (AC) and 2,500 kVA (DC)
- VFD output measurement - External clamps: AC/DC 1,000 A (optional: UT-CS07) - IP67 rating and protection against drops from 5 m
- Overvoltage category: CAT IV 1,000 V and CAT III 1,500 V - Operating environment: -40 °C to 55 °C - Bluetooth app support - Certifications: CE, cETLus, RoHS
Technical specifications: DC voltage measurement (V): Range / Accuracy 600.0 mV / ±(0.3% + 5) 6,000 V / ±(0.2% + 5)
60.00 V / ±(0.2% + 5) 600.0 V / ±(0.2% + 5) 2,500 V / ±(1.0% + 5)
AC voltage measurement (V): Range / Accuracy 600.0 mV / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
6,000 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
60.00 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
600.0 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
1500 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3) VFD (ACV) measurement: Range / Accuracy
600.0 V / 45 Hz to 200 Hz: ± (2.0% + 5) 1,500 V / 45 Hz to 200 Hz: ± (2.0% + 5)
Auto Loz measurement: Range / Accuracy 600.0 V / 45 Hz to 400 Hz: ± (1.5% + 5) 1,500 V / 45 Hz to 400 Hz: ± (1.8% + 5)
AC+DC Voltage Measurement: Range / Accuracy 600.0 mV / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5) 6,000 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
60.00 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
600.0 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
1500 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
Resistance measurement: Range / Accuracy 600.0 ? / ± (0.8% + 5) 6,000 k? / ± (0.5% + 5)
60.00 k? / ± (0.5% + 5) 600.0 k? / ± (0.5% + 5) 6.000 M? / ± (0.5% + 5)
60.00 M? / ± (2.5% + 5) Capacitance measurement: Range / Accuracy 60.00 nF / ± (3.0%)
600.0 nF / ± (3.0% + 5) 6,000 µF / ± (3.0% + 5) 60.00 µF / ± (3.0% + 5)
600.0 µF / ± (3.0% + 5) 6,000 mF / ± (10% + 5) 60.00 mF / ± (10% + 5) - Continuity: 600.0 ? ±(1.0%+5) - diode test (semiconductor junctions): 3.2 V / ± (1.0%+5) - frequency measurement: Range / Accuracy
99.99 Hz / ± (0.02% + 5) 999.9 Hz / ± (0.02% + 5) 9.999 kHz / ± (0.02% + 5)
99.99 kHz / ± (0.02% + 5) 999.9 kHz / ± (0.02% + 5) - Duty cycle: 10 Hz to 10 kHz (10%–90%) ± (2.0% + 30) Temperature measurement: Range / Accuracy –40°C to 1,000°C / ± (1.0% + 30)
-40°F to 1832°F / ± (1.0%+60) Current measurement using the UT-CS07 current loop: Range / Accuracy
- UT-CS07 external clamps (DCA) (optional): 100 A (10 mV/A) and 1000 A (1 mV/A) ±(0.8% + 5)
- UT-CS07 external current clamps (ACA) (optional): 45 to 400 Hz: 100 A (10 mV/A) and 1000 A (1 mV/A) ±(1.0% + 5)
Alternating current 100 A (10 mV/A): Range / Accuracy - active power: 60.00 kW / 150.0 kW (3.0 % + 5)
- apparent power: 60.00 kVA / 150.0 kVA ± (2.0 % + 5) - reactive power: 60.00 kVAr / 150.0 kVAr ± (5.0 % + 5)
- power factor: -1 to 1 1000 A alternating current (1 mV/A): Range / Accuracy
- active power: 600.00 kW / 1,500.0 kW (3.0 % + 5) - apparent power: 600.00 kVA / 1,500.0 kVA ± (2.0 % + 5)
- Reactive power: 600.00 kVAr / 1500.0 kVAr ± (5.0 % + 5) - Power factor: -1 to 1
Direct current 100 A (10 mV/A): 60.00 kVA / 250.0 kVA ±(3.0 %+5)
Direct current 1000 A (10 mV/A): 60.00 kVA / 2500 kVA ± (3.0 % + 5) - Number of display readings: 6000
- analogue bar graph: 33-segment bar display - True RMS - non-contact AC voltage measurement (NCV) - automatic range switching - measurement modes: REL., PEAK - peak measurements: MAX and
Product specifications: - True RMS measurement with 6,000 digits - AC/DC voltage: 1,000 V - Power measurement: 1,500 kVA (AC) and 2,500 kVA (DC)
- VFD output measurement - External clamps: AC/DC 1,000 A (optional: UT-CS07) - IP67 rating and protection against drops from 5 m
- Overvoltage category: CAT IV 1,000 V and CAT III 1,500 V - Operating environment: -40 °C to 55 °C - Bluetooth app support - Certifications: CE, cETLus, RoHS
Technical specifications: DC voltage measurement (V): Range / Accuracy 600.0 mV / ±(0.3% + 5) 6,000 V / ±(0.2% + 5)
60.00 V / ±(0.2% + 5) 600.0 V / ±(0.2% + 5) 2,500 V / ±(1.0% + 5)
AC voltage measurement (V): Range / Accuracy 600.0 mV / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
6,000 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
60.00 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
600.0 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3)
1500 V / 45 Hz to 500 Hz: ± (0.8% + 3); 500 Hz to 1 kHz: ± (1.8% + 3) VFD (ACV) measurement: Range / Accuracy
600.0 V / 45 Hz to 200 Hz: ± (2.0% + 5) 1,500 V / 45 Hz to 200 Hz: ± (2.0% + 5)
Auto Loz measurement: Range / Accuracy 600.0 V / 45 Hz to 400 Hz: ± (1.5% + 5) 1,500 V / 45 Hz to 400 Hz: ± (1.8% + 5)
AC+DC Voltage Measurement: Range / Accuracy 600.0 mV / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5) 6,000 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
60.00 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
600.0 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
1500 V / 45 Hz to 500 Hz: ± (1.5% + 5); 500 Hz to 1 kHz: ± (2.5% + 5)
Resistance measurement: Range / Accuracy 600.0 ? / ± (0.8% + 5) 6,000 k? / ± (0.5% + 5)
60.00 k? / ± (0.5% + 5) 600.0 k? / ± (0.5% + 5) 6.000 M? / ± (0.5% + 5)
60.00 M? / ± (2.5% + 5) Capacitance measurement: Range / Accuracy 60.00 nF / ± (3.0%)
600.0 nF / ± (3.0% + 5) 6,000 µF / ± (3.0% + 5) 60.00 µF / ± (3.0% + 5)
600.0 µF / ± (3.0% + 5) 6,000 mF / ± (10% + 5) 60.00 mF / ± (10% + 5) - Continuity: 600.0 ? ±(1.0%+5) - diode test (semiconductor junctions): 3.2 V / ± (1.0%+5) - frequency measurement: Range / Accuracy
99.99 Hz / ± (0.02% + 5) 999.9 Hz / ± (0.02% + 5) 9.999 kHz / ± (0.02% + 5)
99.99 kHz / ± (0.02% + 5) 999.9 kHz / ± (0.02% + 5) - Duty cycle: 10 Hz to 10 kHz (10%–90%) ± (2.0% + 30) Temperature measurement: Range / Accuracy –40°C to 1,000°C / ± (1.0% + 30)
-40°F to 1832°F / ± (1.0%+60) Current measurement using the UT-CS07 current loop: Range / Accuracy
- UT-CS07 external clamps (DCA) (optional): 100 A (10 mV/A) and 1000 A (1 mV/A) ±(0.8% + 5)
- UT-CS07 external current clamps (ACA) (optional): 45 to 400 Hz: 100 A (10 mV/A) and 1000 A (1 mV/A) ±(1.0% + 5)
Alternating current 100 A (10 mV/A): Range / Accuracy - active power: 60.00 kW / 150.0 kW (3.0 % + 5)
- apparent power: 60.00 kVA / 150.0 kVA ± (2.0 % + 5) - reactive power: 60.00 kVAr / 150.0 kVAr ± (5.0 % + 5)
- power factor: -1 to 1 1000 A alternating current (1 mV/A): Range / Accuracy
- active power: 600.00 kW / 1,500.0 kW (3.0 % + 5) - apparent power: 600.00 kVA / 1,500.0 kVA ± (2.0 % + 5)
- Reactive power: 600.00 kVAr / 1500.0 kVAr ± (5.0 % + 5) - Power factor: -1 to 1
Direct current 100 A (10 mV/A): 60.00 kVA / 250.0 kVA ±(3.0 %+5)
Direct current 1000 A (10 mV/A): 60.00 kVA / 2500 kVA ± (3.0 % + 5) - Number of display readings: 6000
- analogue bar graph: 33-segment bar display - True RMS - non-contact AC voltage measurement (NCV) - automatic range switching - measurement modes: REL., PEAK - peak measurements: MAX and