FNIRSI LC1020E LCR metre and component tester.
The FNIRSI LC1020E is a high-precision, portable digital LCR metre designed for detailed testing of electronic components such as inductors, capacitors and resistors.
Product specifications: - high accuracy: basic measurement accuracy is (±0.05%) with a 4.5-digit display resolution - automatic identification of R/L/C components for fast and efficient measurement
- 5 test frequencies (100 Hz–100 kHz) and 3 voltage levels (0.1 V–0.6 V) for flexible analysis
- Measures L/C/R/Z values with automatic mode switching and displays X/D/Q/?/ESR as secondary parameters for comprehensive component analysis - Intelligent automatic component identification - Multi-frequency and selectable test frequency:
supports 5 test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
offers 3 levels of RMS test voltage: 0.1 V, 0.3 V, 0.6 V – thus providing precise control in various test scenarios
- Sorting and comparison functions: setting of nominal values and tolerances (0.1%–99.9%) for automatic pass/fail assessment with audio-visual prompts for rapid batch testing and quality control
- dual-parameter display on a 2.8" TFT screen: clearly displays both primary and secondary parameters in real time, easy to read anytime, anywhere
- Open-circuit and short-circuit calibration: calibrate test set-ups and eliminate systematic errors to achieve accurate and repeatable results
- Data hold and recording mode: press to hold the measured value; press and hold to switch to recording mode
- Compact and rechargeable design: lightweight, portable body powered by a 3.7 V 3000 mAh lithium battery, ideal for laboratories, production lines and field use
Technical specifications: - Model: LC1020E - Display: 2.8-inch TFT LCD colour display - Basic accuracy: approx. 0.3%
- Test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz - Display digits: main parameter: 4.5 digits / secondary parameter: 4.5 digits
- Measurement parameters: main parameters: AUTO/R/C/L/Z; secondary parameters: X/D/Q/?/ESR - Measurement range: inductance: 0–100 H
capacitance: 0–100 mF resistance: 0–10 M? - test levels: 0.1 V / 0.3 V / 0.6 V - internal offset: 0.0 V / 0.5 V
- Calibration functions: open-circuit calibration, short-circuit calibration - Comparison function: used to calculate the relative error between the measured value of a component and its nominal value, displayed as a percentage, and provides filtered results. Nominal values and tolerances can be set with an adjustable tolerance range from 0.1% to 99.9%.
- Data logging: counter for successful/failed measurements - Test ports: 3-pin socket and 5-pin socket (Kelvin 4-wire measurement) - Output impedance: 100 ohms
- Power supply: built-in 3.7V 3000 mAh Li-Ion battery, USB-C charging - Other settings: language settings, screen brightness, sound settings, auto-off, calibration settings, system information
- Auto-off: yes - Dimensions: 185 × 85 × 35 mm - Weight: approx. 680 g Package contents: - Test leads - Kelvin clamps - USB charging cable
Product specifications: - high accuracy: basic measurement accuracy is (±0.05%) with a 4.5-digit display resolution - automatic identification of R/L/C components for fast and efficient measurement
- 5 test frequencies (100 Hz–100 kHz) and 3 voltage levels (0.1 V–0.6 V) for flexible analysis
- Measures L/C/R/Z values with automatic mode switching and displays X/D/Q/?/ESR as secondary parameters for comprehensive component analysis - Intelligent automatic component identification - Multi-frequency and selectable test frequency:
supports 5 test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
offers 3 levels of RMS test voltage: 0.1 V, 0.3 V, 0.6 V – thus providing precise control in various test scenarios
- Sorting and comparison functions: setting of nominal values and tolerances (0.1%–99.9%) for automatic pass/fail assessment with audio-visual prompts for rapid batch testing and quality control
- dual-parameter display on a 2.8" TFT screen: clearly displays both primary and secondary parameters in real time, easy to read anytime, anywhere
- Open-circuit and short-circuit calibration: calibrate test set-ups and eliminate systematic errors to achieve accurate and repeatable results
- Data hold and recording mode: press to hold the measured value; press and hold to switch to recording mode
- Compact and rechargeable design: lightweight, portable body powered by a 3.7 V 3000 mAh lithium battery, ideal for laboratories, production lines and field use
Technical specifications: - Model: LC1020E - Display: 2.8-inch TFT LCD colour display - Basic accuracy: approx. 0.3%
- Test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz - Display digits: main parameter: 4.5 digits / secondary parameter: 4.5 digits
- Measurement parameters: main parameters: AUTO/R/C/L/Z; secondary parameters: X/D/Q/?/ESR - Measurement range: inductance: 0–100 H
capacitance: 0–100 mF resistance: 0–10 M? - test levels: 0.1 V / 0.3 V / 0.6 V - internal offset: 0.0 V / 0.5 V
- Calibration functions: open-circuit calibration, short-circuit calibration - Comparison function: used to calculate the relative error between the measured value of a component and its nominal value, displayed as a percentage, and provides filtered results. Nominal values and tolerances can be set with an adjustable tolerance range from 0.1% to 99.9%.
- Data logging: counter for successful/failed measurements - Test ports: 3-pin socket and 5-pin socket (Kelvin 4-wire measurement) - Output impedance: 100 ohms
- Power supply: built-in 3.7V 3000 mAh Li-Ion battery, USB-C charging - Other settings: language settings, screen brightness, sound settings, auto-off, calibration settings, system information
- Auto-off: yes - Dimensions: 185 × 85 × 35 mm - Weight: approx. 680 g Package contents: - Test leads - Kelvin clamps - USB charging cable