{"product_id":"multimetr-uni-t-ut139c","title":"Multimeter UNI-T  UT139C","description":"This product comes with a 3-year warranty.\u003cbr\/\u003e\u003cbr\/\u003eThe UNI-T UT139C is a new professional multimeter with True RMS classification and CAT III 600V protection designed for the needs of electricians to measure LV distribution networks in buildings. Innovative and industrial design with protective sleeve ensures impact resistance of the multimeter. The instrument includes a number of extra features such as low impedance voltage measurement (LoZ) (for variants UT139E + UT139S), variable frequency voltage measurement (VFC) (for variants UT139E + UT139S), contactless voltage measurement (NCV), capacitor capacitance measurement, frequency ratio measurement, or temperature measurement. Large and well-arranged LCD TN backlit display ensures better display of measured values. The display range is ± 6,000, for capacitance and frequency 9999. Refresh rate 2 to 3 times per second. The fuses are protected by tube fuses (range 10A fuse FF 10A H \/ 600V (6 x 25mm); range mA \/ µA fuse FF 600mA H \/ 600V (6 x 32mm)). The multimeter is powered by two AA 1.5V alkaline batteries. The measuring range can be selected automatically or manually. Included are test leads with spikes, K-type thermocouple and batteries.\u003cbr\/\u003e\u003cbr\/\u003eUT139C is the ideal choice if you want a professionally equipped multimeter with a range of premium features that is also accurate, clear, safe and very easy to use.\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eProduct parameters (multimeter function) :\u003cbr\/\u003e\u003cbr\/\u003e- True RMS measurement (instrument measures RMS value of AC and voltage)\u003cbr\/\u003e- AC voltage ranges measurement (AC 45 Hz to 1kHz) : \t\t60 mV \/ 600 V\u003cbr\/\u003e- AC current ranges measurement (AC 45 Hz to 1kHz) : \t\t600 µA \/ 10 A\u003cbr\/\u003e- DC voltage ranges measurement : \t\t\t\t60 mV \/ 600 V\u003cbr\/\u003e- DC current ranges measurement : \t\t\t\t600 µA \/ 10 A\u003cbr\/\u003e- ranges resistance measurement : \t\t\t\t600 ? \/ 60 M?\u003cbr\/\u003e- ranges capacitor capacity measurement : \t\t\t9.999 nF \/ 99.99 mF\u003cbr\/\u003e- capacity measurement in relative mode (REL)\u003cbr\/\u003e- Option to connect optional clamp for current measurement up to 60A AC \/ DC\u003cbr\/\u003e- line continuity test (buzzer)\u003cbr\/\u003e- test of diodes and semiconductor transitions at 3.2V\u003cbr\/\u003e- non-contact voltage measurement (NCV)\u003cbr\/\u003e- duty cycle measurement (DCL)\u003cbr\/\u003e- automatic and manual range selection\u003cbr\/\u003e- detection of opposite polarity\u003cbr\/\u003e- Data hold function\u003cbr\/\u003e- display minimum and maximum values\u003cbr\/\u003e- display backlight\u003cbr\/\u003e- automatic shutdown when idle\u003cbr\/\u003e- Low battery indication\u003cbr\/\u003e- overload protection, fuse protection\u003cbr\/\u003e\u003cbr\/\u003eTechnical parameters : \u003cbr\/\u003e\u003cbr\/\u003e-  DC voltage measurement ( input impedance according to range 3 to approx. 10M? ) :\u003cbr\/\u003e         (range    \/  resolution  \/  accuracy  ) \u003cbr\/\u003e     60.00 mV     \/    0.01mV   \/   ±0.5 % + 3\u003cbr\/\u003e     600.0 mV     \/    0.1 mV   \/   ± 0.5 % + 2\u003cbr\/\u003e         6.000 V    \/    1 mV       \/   ± 0.7 % + 3\u003cbr\/\u003e         60.00 V    \/   0.01 V      \/    ± 0.7 % + 3\u003cbr\/\u003e         600.0 V    \/     0.1 V      \/    ± 0.7 % + 3\u003cbr\/\u003e            \u003cbr\/\u003e\u003cbr\/\u003e-  AC voltage measurementí  ( input impedance according to range 3 to approx. 10M? ) :\u003cbr\/\u003e        (  range   \/  resolution   \/   accuracy ) \u003cbr\/\u003e                 60.00 mV  \/ 0.01 mV    \/  ± 1.0 % + 3 \u003cbr\/\u003e                 600.0 mV  \/   0.1 mV    \/  ± 1.0 % + 3 \u003cbr\/\u003e                     6.000 V  \/   0.001 V    \/  ± 0.8 % + 3 \u003cbr\/\u003e                     60.00 V  \/     0.01 V    \/  ± 0.8 % + 3 \u003cbr\/\u003e                     600.0 V  \/       0.1 V    \/  ± 0.8 % + 3 \u003cbr\/\u003e  VFC 200 to 600.0 V \/        0.1 V    \/  ± 4.0 % + 3    \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e-  DC current measurement :\u003cbr\/\u003e      (  range   \/  resolution   \/   accuracy ) \u003cbr\/\u003e       600.0 µA    \/     0.1 µA    \/  ± 0.7 % + 2 \u003cbr\/\u003e        6000 µA    \/        1 µA    \/  ± 0.7 % + 2 \u003cbr\/\u003e      60.00 mA    \/  0.01 mA   \/  ± 0.7 % + 2 \u003cbr\/\u003e      600.0 mA    \/    0.1 mA   \/  ± 0.7 % + 2 \u003cbr\/\u003e          6.000 A    \/   0.001 A   \/  ± 1.0 % + 3 \u003cbr\/\u003e          10.00 A    \/     0.01 A   \/  ± 1.0 % + 3 \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e-  AC current measurement :\u003cbr\/\u003e       (  range   \/  resolution   \/   accuracy ) \u003cbr\/\u003e         600.0 µA    \/    0.1 µA    \/  ± 1.0 % + 3 \u003cbr\/\u003e          6000 µA    \/       1 µA    \/  ± 1.0 % + 3 \u003cbr\/\u003e        60.00 mA    \/ 0.01 mA   \/  ± 1.0 % + 3 \u003cbr\/\u003e        600.0 mA    \/   0.1 mA   \/  ± 1.0 % + 3 \u003cbr\/\u003e            6.000 A   \/   0.001 A    \/  ± 1.2 % + 3 \u003cbr\/\u003e            10.00 A   \/     0.01 A    \/  ± 1.2 % + 3 \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e-  Resistance measurement : \u003cbr\/\u003e        (  range   \/  resolution   \/   accuracy ) \u003cbr\/\u003e          600.0 ?    \/         0.1 ?     \/  ± 1.0 % + 2 \u003cbr\/\u003e        6.000 k?    \/   0.001 k?     \/  ± 0.8 % + 2 \u003cbr\/\u003e        60.00 k?    \/     0.01 k?     \/  ± 0.8 % + 2 \u003cbr\/\u003e        600.0 k?    \/       0.1 k?     \/  ± 0.8 % + 2 \u003cbr\/\u003e       6.000 M?   \/ 0.001 M?     \/   ± 1.2 % + 3 \u003cbr\/\u003e       60.00 M?   \/   0.01 M?     \/   ± 1.5 % + 5 \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e-  Capacitance measurement :\u003cbr\/\u003e                  (  range   \/  resolution   \/   accuracy ) \u003cbr\/\u003e                     9.999 nF   \/    0.001 nF     \/    při REL módu ± 4 % + 10 \u003cbr\/\u003e   99.99 nF až 999.9 µF \/ 0.01 nF až 0.1 µF   \/ ± 4 % + 10 \u003cbr\/\u003e9.999 mF až 99.99 mF \/ 0.001 mF až 0.01 mF    \/ ± 10 % \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e-  Frequency and duty cycle measurement :\u003cbr\/\u003e                    (   range          \/                resolution                 \/     accuracy  ) \u003cbr\/\u003e9.999 Hz až 9.999 MHz       \/     0.001 Hz až 0.001 MHz    \/    ± 0.1 % + 4 \u003cbr\/\u003e            0.1 % až 99.9 %       \/                     0.1 %                  \/   Reference only \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e-  Temperature measurement in °C  :\u003cbr\/\u003e            (  range      \/     resolution    \/     accuracy ) \u003cbr\/\u003e         - 40 až 40°C   \/           1°C      \/       ± 4 \u003cbr\/\u003e       \u003e 40 až 500°C  \/           1°C      \/ ± 1.0 % + 4 \u003cbr\/\u003e    \u003e 500 až 1000°C \/           1°C      \/ ± 2.0 % + 4 \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e-  Temperature measurement in °F  :\u003cbr\/\u003e          (    range        \/    resolition    \/     accuracy ) \u003cbr\/\u003e       - 40 až 104°F    \/          1°F         \/       ± 5 \u003cbr\/\u003e    \u003e 104 až 932°F    \/          1°F         \/    ± 1.5 % + 5 \u003cbr\/\u003e  \u003e 932 až 1832°F    \/          1°F         \/    ± 2.5 % + 5 \u003cbr\/\u003e\u003cbr\/\u003e-  With the thermostatic probe (cell type K), only temperatures up to 230°C  \u003cbr\/\u003e\u003cbr\/\u003e-  Display type : LCD TN \u003cbr\/\u003e-  Display diagonal : 68 mm \u003cbr\/\u003e-  Sampling frequency : 3 \/ s \u003cbr\/\u003e-  Number of digits : 6000 \u003cbr\/\u003e-  Multimeter dimensions : 170 x 80 x 48 mm \u003cbr\/\u003e-  Power supply : 2 x AA 1.5 V battery (included) \u003cbr\/\u003e-  Thermal probe with type K (included) \u003cbr\/\u003e-  Test leads with tips (included) \u003cbr\/\u003e-  Fuse F1 : 6 x 32 mm FF 600 mA H 600 V (installed) \u003cbr\/\u003e-  Fuse F2 : 6 x 25 mm FF 10 A H 600 V (installed) \u003cbr\/\u003e-  Fall resistance : 1 m \u003cbr\/\u003e-  Weight: approx. 354 g (including batteries) \u003cbr\/\u003e-  Operating temperature: - 10 to 50°C \u003cbr\/\u003e-  The device meets following standards: \u003cbr\/\u003e      cETLus, CAT III 600V, double insulation, overload protection 600V-PTC, pollution class II \u003cbr\/\u003e      EN 61326-1: 2013; EN 61326-2-2: 2013 \u003cbr\/\u003e      EN 61010-1: 2010; EN 61010-2-030: 2010; EN 61010-2-033: 2012 \u003cbr\/\u003e      Complies with UL STD standards: 61010-1, 61010-2-030 \u003cbr\/\u003e      Certified by CSA STD. C22.2 No. 61010-1, 61010-2-030, 61010-2-033 \u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003ePackage contents :\u003cbr\/\u003e\u003cbr\/\u003e-  multimeter UT139C with impact plastic cover\u003cbr\/\u003e-  2 x AA 1.5 V batteries\u003cbr\/\u003e-  F1 fuse: 6 x 32mm FF 600mA H 600V (in device)\u003cbr\/\u003e-  F2 Fuse: 6 x 25mm FF 10A H 600V (in device)\u003cbr\/\u003e-  thermo probe with cell type K (included)\u003cbr\/\u003e-  test leads with spikes (included)\u003cbr\/\u003e-  instructions for use in Czech, Slovak and English\u003cbr\/\u003e\u003cbr\/\u003e-  Manufacturer: UNI-TREND \u003cbr\/\u003e-  www.uni-t.cz","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52541777510738,"sku":"07720154","price":1150.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9624\/1490\/files\/07720154_7cb44cbb-acc9-4bf2-85ba-4e130bd61838.png?v=1784727399","url":"https:\/\/tipa.eu\/en\/products\/multimeter-unit-ut139c-1","provider":"TIPA","version":"1.0","type":"link"}