Description
UT171 Series Multimeters are hand-held multimeters with automatic and manual range switching and 4 3/4 - 4 5/6 digit resolution. The devices belong to the upper middle class, excel in quality design and reliability and are also suitable for industrial use. They can measure AC / DC voltages and currents, resistance, diode test, continuity test, capacitance, frequency, duty cycle, temperature, 4-20mA current loop, conductivity, VFC, NCV. The devices enable data storage and connection via USB with optical separation or via Bluetooth.
The UNI-T UT171C multimeter is the best instrument in the UT171 series.
Unlike the UT171A, the UT171C has a higher range for measuring resistance and capacitance, and also measures conductivity (inverse resistance). The display type is OLED with a dot matrix. The display range is ± 60000 for voltages, currents and frequencies and ± 6000 for capacitance measurements. The display includes an analog bar-graph with 31-part. Refresh rate 4 to 5 times per second. The fuses are protected by tube fuses (range 10A fuse FF 10A H / 1000V (10 x 38mm); range mA / µA fuse FF 800mA H / 600V (6 x 32mm)). The device can test its own fuses (without opening the device). The multimeter is powered by a 7.4V / 1800mAh lithium battery. The measuring range can be selected automatically or manually. Included are test leads with tips in safety category CAT III 1000V and CAT IV 600V.
Product parameters:
- fully complies with IEC / EN61010-1, and have double insulation
- categorized as CAT III 1000V - internal el. installation including three-phase distribution
- categorized as CAT IV 600V - outdoor el. installation (belay elements, beginning of internal installation)
- The maximum display is 60000, an OLED type inverted display with a dot matrix
- Display of 60000 frequency measurement display
- Display for capacity measurement 6000
- Refresh rate for most measurements 4 to 5 times per second
- setting ranges automatic or manual
- AC voltage measuring ranges : 600 mV / 1000 V
- AC currents measuring ranges : 600 μA / 10 A
- DC voltage measuring ranges : 600 mV / 1000 V
- DC currents measuring ranges : 600 μA / 10 A
- Measuring ranges for currents using 60 and 600 A pliers
- resistance measuring ranges : 600 Ω / 60 MΩ
- capacitor capacity measuring ranges : 60.00 nF / 60.00 mF
- measuring ranges from : 60 Hz to 10 MHz
- Rectangular signal generator 0.5Hz to 4800Hz
- duty ratio measuring range : 1,0% to 99%
- measuring range duty cycle : 100.0ms to 0.100µs
- conductivity measuring range : 60nS
- temperature measuring range : -40°C ~ 1000°C, (with supplied K-type thermocouple nickel-chromium-nickel-silicon only up to + 230°C)
- High precision
- Analogue scale Bargraf, 31 divisions
- TRMS, measurement of voltage rms voltage st. voltage and currents
- during AC voltage measurement, the frequency display or the voltage duty cycle can be measured on the secondary display
- on the secondary display it is also possible to measure the AC component mounted on DC voltage
- datalogging 1000 values
- relative measurement mode
- measurement of MAX and MIN peaks with 1ms response
- Indication of poor wiring
- Low battery indication
- automatic shutdown (sleep when idle)
- Overload protection of voltage inputs
- protection of surge inputs with fast fuses
- input impedance 10MΩ
- Non-contact voltage detection without test probes
- test of diodes and semiconductor transitions with voltage 0 to 3V
- Battery powered by LiIon 7.4V / 1.800mAh
- supplied USB cable with converter, software can be downloaded from the manufacturer's website: https://meters.uni-trend.com/product/ut171-series/#Docs
- Option to purchase a Bluetooth adapter UT-D08
- supplied DC 10V / 500mA power supply with accessories
- measurement in elmag is also possible. field with intensity 1V / m with additional error 5%
Technical parameters :
( accuracy is defined at 23 ° C ± 5 ° C and relative humidity less than or equal to 75% )
- DC voltage measurement (input impedance is 10MΩ) :
( range / resolution / accuracy)
600.00 mV / 10µV / ± 0.025 % + 5
6.0000 V / 0.1 mV / ± 0.025 % + 5
60.000 V / 1mV / ± 0.025 % + 5
600.00 V / 10mV / ± 0.03 % + 5
1000.0 V / 100mV / ± 0.03% + 5
- AC voltage measurement (input impedance is 10MΩ, 45Hz to 1kHz ) :
( range / resolution / accuracy )
600.00 mV / 10µV / ± 0.4 % + 40
6.0000 V / 0.1 mV / ± 0.025 % + 5
60.000 V / 1mV / ± 0.025 % + 5
600.00 V / 10mV / ± 0.03 % + 5
1000.0 V / 100mV / ± 0.03% + 5
LoZ 100.0 V / 0.1 V / ± 2.0 % + 10
V.F.C. 600V/1000V / 0.01 V/0.1 V / ± 2.0 % + 10
- DC current measurement :
( range / resolution / accuracy )
600.0 μA / 0.01 μA / ± 0.25 % + 20
6000.0 μA / 0.1 μA / ± 0.25 % + 2
60.000 mA / 1μA / ± 0.7 % + 2
600.0 mA / 10μA / ± 0.15% + 2
6.000 A / 0.1mA / ± 0.5 % + 3
10.000 A / 1m A / ± 0.5 % + 2
% (4-20mA) / 0,01% / ± 0.5 % + 2
- AC current measurement ( 45Hz to 1kHz ) :
( range / resolution / accuracy )
600.00 μA / 0.01 μA / ± 0.75 % + 20
6000.0 μA / 0.1 μA / ± 0.75 % + 20
60.000 mA / 1µA / ± 0.75 % + 20
600.000mA / 10µA / ± 0.75 % + 20
6.0000 A / 0.1mA / ± 1.5 % + 20
10.000A / 1m A / ± 1.5 % + 5
- DC current measurement using current clamp :
range 60A ( při 10mV/A ) / resolution 0,001A / accuracy ±(1.0% + 30)
range 600A ( při 1mV/A ) / resolution 0,01A / accuracy ±(1.0% + 30)
- AC current measurement using current clamp :
range 60A ( at 10mV/A ) / resolution 0,001A / accuracy ±(1.2% + 30)
range 600A ( at 1mV/A ) / resolution 0,01A / accuracy ±(1.2% + 30)
- Resistance and conductivity measurement :
( range / resolution / accuracy )
600.00 Ω / 0.01 Ω / ± 0.05 % + 10
6.0000 kΩ / 0.1 Ω / ± 0.05 % + 2
60.000 kΩ / 1Ω / ± 0.05 % + 2
600.00 kΩ / 10Ω / ± 0.05 % + 2
6.0000 MΩ / 100 Ω / ± 0.15% + 5
60.000 MΩ / 1 kΩ / ± 3 % + 2
60.00nS / 0.01nS / ± 1 % + 10 (S = Siemens unit)
- Capacitor capacity measurement :
( range / resolution / accuracy )
6.000 nF / 1 pF / ± 3.0 % + 30
60.00 nF až 600.0 µF / 10pf až 100 nF / ± 2.5 % + 5
6.000 mF až 60.00 mF / 1 µF až 10 µF / ± 10 %
- Frequency, duty cycle and period measurement :
( range / resolution / accuracy )
60.000 Hz až 10.000 MHz / 0.0001 Hz až 0.001 MHz / ± 0.01 % + 5
0.1 % až 99.9 % / 0.1 % / ± 3.0 % + 40
100.0ms až 0.100 µs / 0.1ms až 0.001µs / ± 0.1 % + 5
- Rectangular signal generator :
Frequency 0.5Hz až 4800Hz / 0.1Hz is the stepping level / accuracy ± 0.01 % + 5
Duty ratio 0% až 100% / 0.1% is the stepping level / accuracy ± 0.5 %
Amplitude / 0.8Vp / accuracy ± 0.2Vp
- Display type inverse, OLED with dot matrix
- sampling frequency : 4 to 5 / sec
- number of digit : 60000
- Analog line : 31 segments
- Power supply : battery LiIon 7,4V / 1800mAh
- fuse protection 10A with fuse FF 10A H / 1000V (10 x 38mm)
- fuse protection mA / µA fuse FF 800mA H / 1000V (6 x 32mm)
- instrument dimensions : 206 x 95 x 53 mm
- weight: approx. 500 g (including batteries)
- working temperature : 0 ° C to 40 ° C
- working relative humidity at 0 ° C to 30 ° C less than or equal to 75%, at 30 ° C to 40 ° C less than or equal to 50%
- storage temperature : - 10 ° C to 50 ° C
- Possibility to purchase current clamp, for range up to 600A
- The device meets the standards :
cETLus, CAT III 1000V, CAT IV 600V, double insulation, overload protection greater than 1000V
EN 61326-1: 2013; EN 61326-2-2: 2013
EN 61010-1: 2010; EN 61010-2-030: 2010; EN 61010-2-033: 2012
Conforms to UL STD .: 61010-1, 61010-2-030
Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030, 61010-2-033
- Manufacturer : UNI-TREND
- www.uni-t.cz
Package contents :
- Multimeter UT171C with storage case
- LiIon battery 7.4V / 1800mAh - in the device
- Fuse F1 : FF 800mA H 1000V (6 x 32mm) - in the device
- Fuse F2 : FF 10A H 1000V (10 x 38mm) - in the device
- USB cable with opto-el. converter
- thermocouple type K (nickel-chromium-nickel-silicon) up to + 230 ° C)
- test leads with CAT III 1000V, CAT IV 600V tips
- DC power supply 10V / 500mA with accessories
- instructions for use in Czech, Slovak and English
Documents available for download