{"product_id":"multimetr-uni-t-ut60bt","title":"Multimeter UNI-T  UT60BT","description":"This product comes with a 3-year warranty.\u003cbr\/\u003e\u003cbr\/\u003eThe UT60BT is a digital multimeter with a display range of 9999, which allows the measurement of true RMS values ??of voltages and currents with automatic and manual range selection. It has 1000V rms overload protection on all ranges, the current range is protected by a 10A \/ 1000V, 6.35 x 32mm tubular fuse. If you approach the limit values ???990.0V \/ ?9.900A when measuring voltages and currents, an alarm sounds and the \"OL\" character is displayed when the limit values ??are exceeded. It also allows the measurement of resistance, capacity, temperature, frequency, duty cycle, circuit continuity and semiconductor junctions. The circuit is optimized for non-contact electric field measurement in two subranges. The multimeter is equipped with a modern processor with a fast analog-to-digital converter (3 times \/ s conversion) and with the transmission of measured values ??via Bluetooth via low-energy wireless technology 802.15.4. , to a mobile phone or tablet with the Connect application installed.\u003cbr\/\u003e\u003cbr\/\u003eThe entire construction of the multimeter is equipped with a durable cover with double insulation and has European CE certification and meets the safety classification CAT II 1000V \/ CAT III 600V. The device is suitable for work in a laboratory or workshop, as well as for common electrical practice. It is powered by standard batteries 3 pcs x 1.5V, AAA, which thanks to low consumption lasts up to 500 hours.\u003cbr\/\u003e\u003cbr\/\u003eProduct parameters :\u003cbr\/\u003e\u003cbr\/\u003e- backlit display range: \t\t\t\t\t9999\u003cbr\/\u003e- voltage measurement: \t\t\t\t\tup to ± 1000V \/ DC \/ AC rms\u003cbr\/\u003e- current measurement: \t\t\t\t\tup to ± 10A \/ DC \/ AC rms\u003cbr\/\u003e- resistance measurement: \t\t\t\t\tup to 99.99M?\u003cbr\/\u003e- capacity measurement: \t\t\t\t\tup to 9,999mF\u003cbr\/\u003e- temperature measurement: \t\t\t\t\twith supplied type K probe up to 250 ° C\u003cbr\/\u003e- frequency measurement: \t\t\t\t\tup to 9.999MHz\u003cbr\/\u003e- duty cycle measurement: up to 1kHz\u003cbr\/\u003e- measurement modes: \t\t\t\t\tauto \/ manual \/ REL \/ RMS \/ HOLD \/ NCV EFLo \/ NCV EFHi\u003cbr\/\u003e- circuit continuity measurement\u003cbr\/\u003e- measurement of semiconductor junctions\u003cbr\/\u003e- non-contact NCV measurement\u003cbr\/\u003e- optical and acoustic alarms\u003cbr\/\u003e- Bluetooth for transmission of measured data\u003cbr\/\u003e- protection of voltage inputs against overload above 1000V\u003cbr\/\u003e- protection of current input 10A by fast fuse\u003cbr\/\u003e- input impedance approx. 10M? for DCV, in the DCmV range then 3G?\u003cbr\/\u003e- power supply: \t\t\t\t\t\t3 x 1.5V, AAA\u003cbr\/\u003e- consumption in low power consumption during measurement: \tabout 2 mA\u003cbr\/\u003e- sleep consumption: \t\t\t\t\t\u003c30 µA\u003cbr\/\u003e- operation on one set of batteries: \t\t\t\t500 hours\u003cbr\/\u003e- low battery indication: \t\t\t\t\tyes\u003cbr\/\u003e- automatic shutdown (sleep on inactivity): \t\t\tyes, after 15 minutes\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eTechnical parameters :\u003cbr\/\u003e\u003cbr\/\u003e- DC voltage measurement (input impedance is about 3G? in the DCmV range, 10M? in other ranges):\u003cbr\/\u003e            (range \/ resolution \/ accuracy)\u003cbr\/\u003e         9.999 mV   \/    0.001mV    \/  ± (0.7 % + 8)\u003cbr\/\u003e         99.99 mV   \/     0.01 mV    \/  ± (0.7 % + 8)\u003cbr\/\u003e         999.9 mV   \/       0.1 mV    \/  ± (0.5 % + 3)\u003cbr\/\u003e         9.999 V      \/    0.001 V       \/  ± (0.5 % + 3) \u003cbr\/\u003e         99.99 V      \/         0.1V       \/  ± (0.5 % + 3)\u003cbr\/\u003e         999.9 V      \/         0.1V       \/  ± (0.5 % + 3)\u003cbr\/\u003e- Maximum input voltage: ± 1000V, alarm sounds at 990.0V, \"OL\" is displayed at \u003e1000V.\u003cbr\/\u003e- Overload protection 1000V RMS (DC \/ AC)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- AC voltage measurement (input impedance approx. 10M?,):\u003cbr\/\u003e                  (range \/ resolution \/ accuracy in the range 40Hz to 400Hz, sine RMS)\u003cbr\/\u003e                9.999 mV   \/    0,001mV    \/  ± (1 % + 3)\u003cbr\/\u003e                99.99 mV   \/     0,01 mV    \/  ± (1 % + 3)\u003cbr\/\u003e                999.9 mV   \/       0,1 mV    \/  ± (0,8 % + 3)\u003cbr\/\u003e                9.999 V      \/    0,001 V       \/  ± (0,8 % + 3) \u003cbr\/\u003e                999.9 V      \/         0,1V       \/  ± (0,8 % + 3)                     \u003cbr\/\u003e- Maximum input voltage: AC1000V, alarm sounds at 990.0V, \"OL\" is displayed at \u003e1000V.\u003cbr\/\u003e- Overload protection 1000V RMS (DC \/ AC)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- DC current measurement:\u003cbr\/\u003e        (   range   \/ resolution \/ accuracy)\u003cbr\/\u003e       999.9 µA   \/    0.1 µA     \/ ± (0.8% + 3)\u003cbr\/\u003e       999.9 mA  \/    0.1 mA   \/ ± (1.0% + 3)\u003cbr\/\u003e          9.999 A  \/ 0.001 A      \/ ± (1.0% + 3)\u003cbr\/\u003e- Alarm sounds at ?9,900A, \"OL\" is displayed at \u003e10.00 A.\u003cbr\/\u003e- Overload protection: 1000V RMS, fast fuse 10A\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- AC current measurement:\u003cbr\/\u003e        (   range   \/   resolution   \/ accuracy in the range of 40Hz to 400Hz)\u003cbr\/\u003e       999.9 µA   \/ 0.1 µA      \/ ± (1.0% + 3)\u003cbr\/\u003e       999.9 mA  \/ 0.1 mA    \/ ± (1.2% + 3)\u003cbr\/\u003e       9.999 A     \/ 0.001 A    \/ ± (1.2% + 3)\u003cbr\/\u003e- Alarm sounds at ?9,900A, \"OL\" is displayed at \u003e10.00 A.\u003cbr\/\u003e- Overload protection: 1000V RMS, fast fuse 10A\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Resistance measurement:\u003cbr\/\u003e        (    range    \/  resolution  \/ accuracy)\u003cbr\/\u003e          999.9 ?    \/      0.1 ?      \/   ± (0.8 % + 2) \u003cbr\/\u003e        9.999 k?    \/  0.001k?     \/   ± (0.8 % + 2) \u003cbr\/\u003e        99.99 k?    \/   0.01 k?     \/   ± (0.8 % + 2) \u003cbr\/\u003e        999.9 k?    \/     0.1 k?     \/   ± (0.8 % + 2) \u003cbr\/\u003e       9.999 M?   \/ 0.001 M?    \/   ± (1.5 % + 3) \u003cbr\/\u003e       99.99 M?   \/   0.01 M?    \/   ± (2.0 % + 5) \u003cbr\/\u003e- 1000V overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Capacitor capacity measurement:\u003cbr\/\u003e           (   range   \/   resolution  \/   accuracy)\u003cbr\/\u003e               9.999 nF \/  0,001 nF    \/ ± (4% + 10)\u003cbr\/\u003e               99.99 nF \/    0.01 nF    \/ ± (4% + 5)\u003cbr\/\u003e               999.9 nF \/    0.01 nF    \/ ± (4% + 5)\u003cbr\/\u003e               9.999 \/F \/   0.001 µF    \/ ± (4% + 5)\u003cbr\/\u003e               99.99 µF \/    0.01 µF    \/ ± (4% + 5)\u003cbr\/\u003e               999.9 µF \/      0.1 µF    \/ ± (4% + 5)\u003cbr\/\u003e              9.999 mF \/ 0.001 mF   \/ ± (10%)\u003cbr\/\u003e- For kapacity100nF capacities, use REL mode\u003cbr\/\u003e- 1000V overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Frequency measurement:\u003cbr\/\u003e                     (     range    \/            resolution          \/   accuracy)\u003cbr\/\u003e 99.99 Hz to 9.999 MHz  \/ 0.01 Hz to 0.001 MHz \/ ± (0.1% + 5)\u003cbr\/\u003e- Overload protection 1000V RMS (DC \/ AC)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Duty cycle measurement for square waves ?10kHz:\u003cbr\/\u003e              (      range   \/   resolution   \/   accuracy  )\u003cbr\/\u003e        0.1%  to 99.9% \/        0.1%       \/    ± (3% + 5)\u003cbr\/\u003eOverload protection 1000V RMS (DC \/ AC)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e - Diode test:\u003cbr\/\u003evoltage at terminals without load about 3.3 V\u003cbr\/\u003ethe voltage drop at a good silicon junction is 0.5 to 0.8 V\u003cbr\/\u003emeasurement resolution 0.001 V\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Circuit continuity test:\u003cbr\/\u003ethe buzzer tone will not sound if the resistance is greater than 30 ?\u003cbr\/\u003ethe tone sounds if the resistance is less than 30 ?\u003cbr\/\u003eOverload protection 1000V RMS (DC \/ AC)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Temperature measurement:\u003cbr\/\u003e                   (      range   \/   resolution   \/   accuracy  )\u003cbr\/\u003e            -40 ° C to 0 ° C \/         1 ° C       \/    ± 4 ° C\u003cbr\/\u003e           0 ° C to 100 ° C \/          1 ° C       \/    ± (1.0% + 5)\u003cbr\/\u003e     100 ° C to 1000 ° C \/          1 ° C       \/    ± (2.0% + 5)\u003cbr\/\u003e\u003cbr\/\u003e          -40 ° F to 32 ° F \/           1 ° F       \/    ± 5 ° F\u003cbr\/\u003e        \u003e 32 ° F - 212 ° F \/           1 ° F       \/    ± (1.5% + 5)\u003cbr\/\u003e    \u003e 212 ° F - 1832 ° F \/           1 ° F       \/    ± (2.5% + 5)\u003cbr\/\u003eThe K-type thermocouple in the accessory is only usable for measuring temperatures below 250 ° C \/ 482 ° F.\u003cbr\/\u003e1000 V RMS overload protection (DC \/ AC)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eGeneral characteristics :\u003cbr\/\u003e\u003cbr\/\u003e- ambient operating temperature: \t\t0 ° C to 40 ° C\u003cbr\/\u003e- storage temperature: \t\t\t-10 ° C - 50 ° C (14 ° F - 122 ° F)\u003cbr\/\u003e- working relative humidity: \t\t\t?75% (0 ° C to 30 ° C), ?50% (30 ° C to 40 ° C)\u003cbr\/\u003e- working altitude: \t\t\t\t0 to 2000m\u003cbr\/\u003e- environment of use: \t\t\tindoor use\u003cbr\/\u003e- EMC resistance: \t\t\t\tfor radio frequency field 1V \/ m\u003cbr\/\u003e- power supply: \t\t\t\t3 x 1.5V, AAA\u003cbr\/\u003e- product color: \t\t\t\tred and gray\u003cbr\/\u003e- net product weight: \t\t\t290 g\u003cbr\/\u003e- product weight: \t\t\t\tabout 400g (including batteries)\u003cbr\/\u003e- product size: \t\t\t\t169 x 81 x 46 mm\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eContents of individual packaging :\u003cbr\/\u003e\u003cbr\/\u003e- UT60BT multimeter with storage case: \t\t\t1pc\u003cbr\/\u003e- battery 1.5V, AAA: \t\t\t\t\t3pcs\u003cbr\/\u003e- fuse F1: \t\t\t\t\t\tF 10A \/ 250V (6.35 x 32mm) - in the device: 1pc\u003cbr\/\u003e- test cables with spikes in category CAT II 1000V \/ CAT III 600V: 1pair\u003cbr\/\u003e- temperature probe: \t\t\t\t1pc\u003cbr\/\u003e- instructions for use: \t\t\t\t1pc\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eWholesale packaging :\u003cbr\/\u003e\u003cbr\/\u003e- standard quantity in a carton: \t\t\t\t20pcs\u003cbr\/\u003e- standard carton size: \t\t\t\t420 x 320 x 300 mm\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Manufacturer: UNI-TREND\u003cbr\/\u003e- www.uni-t.cz","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52554437558610,"sku":"07720292","price":14504.81,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9624\/1490\/files\/07720292_dffe3bb4-cf14-436d-964c-fae828792752.png?v=1787843868","url":"https:\/\/tipa.eu\/en-hu\/products\/multimeter-unit-ut60bt-1","provider":"TIPA","version":"1.0","type":"link"}